Thermal Management for Boxed
IntelŪ PentiumŪ III Processor-Based PCs
Updated January 2000
Introduction
Systems using IntelŪ PentiumŪ III processors all require
thermal management. The reader should have a general knowledge of and experience with PC
operation, integration, and thermal management. Integrators who follow the recommendations
presented can provide their customers with more reliable PCs and will see fewer customers
returning with thermal management issues. (The term "boxed PentiumŪ III
processors" refers to processors packaged for use by system integrators.)
Allowing processors to operate at temperatures beyond
their maximum specified operating temperature may shorten the life of the processor and
can cause unreliable operation. When building quality systems using the boxed Pentium III
processor, it is imperative that you carefully consider the thermal management of the
system and verify the system design with thermal testing. This document details specific
thermal requirements of the boxed Pentium III processor. System integrators using the
boxed PentiumŪ III processor should become familiar with this document as well as the two
related documents listed below
Thermal Management
The term "thermal management" refers to two major
elements: a heatsink properly mounted to the processor, and effective airflow through the
system chassis. The ultimate goal of thermal management is to keep the processor at or
below its maximum operating temperature.
Proper thermal management is achieved when heat is
transferred from the processor to the system air, which is then vented out of the system.
Boxed PentiumŪ III processors are shipped with a high-quality fan heatsink, which can
effectively transfer processor heat to the system air. It is the responsibility of the
system integrator to ensure adequate system airflow.
Fan Heatsink
The fan heatsink included with the boxed PentiumŪ III
processor must be securely attached to the processor. Thermal interface material (already
applied) provides effective heat transfer from the processor to the fan heatsink. The fan
cable provides power to the fan by connecting to a motherboard-mounted power header and
also allows the fan to provide fan speed information to the motherboard. (Only
motherboards with hardware monitoring circuitry can use the fan speed signal.)
The fan is a high-quality ball bearing fan that provides a
good local air stream. This air stream transfers heat from the heatsink to the air inside
the system. However, moving heat to the system air is only half the task. Sufficient
system airflow is also needed in order to exhaust the air. Without a steady stream of air
through the system, the fan heatsink will re-circulate warm air, and therefore may not
cool the processor adequately.
Chassis
Recommendations
Intel recommends the use of ATX and microATX form factor
boards and chassis for the boxed PentiumŪ III processor. The ATX and microATX form
factors provide consistency of airflow to the processor and simplify PC assembly and
upgrade.
PentiumŪ
III Processor Thermal Specifications
Table 1 lists the power dissipation of boxed PentiumŪ III
processors. Use the thermal test methodology described in "Thermal Testing with
Thermocouples and Thermal Meters on Intel Boxed Processor-Based Desktop PCs" to test
thermal management of boxed Pentium III processor-based systems. When building 242-contact
slot connector systems that will feature boxed Pentium III processors, testing should be
performed using the 600-MHz or a 600B-MHz processor because it dissipates the most power.
When building 370-pin socket systems that will feature boxed Pentium III processors,
testing should be performed using the 800-MHz or 800EB-MHz processor because it dissipates
the most power.
Table 1 lists the boxed PentiumŪ III processor
temperature specifications.
Table 1. Boxed
PentiumŪ III Processor Thermal Specifications1
- The maximum operating temperature and maximum power specification are
specifications from the processor datasheet. The recommended fan inlet temperature (TA)
and the recommended heatsink base temperature (THS) are not specification, see
note 3 and 4. For more information on PentiumŪ III processor specifications, see the PentiumŪ III Processor
Datasheet.
- The junction temperature (TJ) can be determined using the
thermal diode in the processor core. For more information, see the AP-905 PentiumŪ III
Processor Thermal Design Guidelines (order # 245087).
- The recommended fan inlet temperature (TA) should be measured
at the inlet of the fan heatsink on the boxed processor (see Figure 1
and Figure 2). This is a maximum value and a recommendation only,
not a specification.
- The recommended heatsink base temperature (THS) should be
measured at the center of the top of the heatsink base near the processor markings (see Figure 1). This is a maximum value and a recommendation only, not a
specification.
- This method of validation is not appropriate for this processor.
|
|
A simple evaluation of the
temperature of the heatsink base can provide confidence in the system's thermal
management. For boxed PentiumŪ III processors in the S.E.C.C.2 form factor, the testing
point is at the center of the heatsink base on the top of the processor near to the
processor marking area (see Figure 1). The document "Thermal
Testing with Thermocouples and Thermal Meters on Intel Boxed Processor-Based PCs"
describes how to determine the temperature of this location while running a high power
application. Evaluation of test data makes it possible to determine if a system has
sufficient thermal management for the boxed processor. A more general evaluation can be
performed by testing the temperature of air entering the fan inlet. Table
1 lists the recommended temperature that the heatsink base test point or the air inlet
temperature should remain below during the thermal evaluation of a system.
Figure 1. S.E.C.C.2 Boxed PentiumŪ III Processor
Temperature Test Locations
For boxed PentiumŪ III processors in the
FC-PGA package, the testing point is 0.3 inches above the center of the fan inlet. (see Figure 2).
Figure 2. FC-PGA Boxed PentiumŪ III Processor
Temperature Test Locations
Fahrenheit to
Celsius Conversion Chart
| ° F |
° C |
° F |
° C |
° F |
° C |
° F |
° C |
59.0 |
15 |
89.6
|
32
|
120.2 |
49 |
150.8
|
66
|
60.8 |
16 |
91.4
|
33
|
122.0 |
50 |
152.6
|
67
|
62.6 |
17 |
93.2
|
34
|
123.8 |
51 |
154.4
|
68
|
64.4 |
18 |
95.0
|
35
|
125.6 |
52 |
156.2
|
69
|
66.2 |
19 |
96.8 |
36
|
127.4 |
53 |
158.0
|
70
|
68.0 |
20 |
98.6
|
37
|
129.2 |
54 |
159.8
|
71
|
69.8 |
21 |
100.4
|
38
|
131.0 |
55 |
161.6
|
72
|
71.6 |
22 |
102.2
|
39
|
132.8 |
56 |
163.4
|
73
|
73.4 |
23 |
104.0
|
40
|
134.6 |
57 |
165.2
|
74
|
75.2 |
24 |
105.8
|
41
|
136.4 |
58 |
167.0
|
75
|
77.0 |
25 |
107.6
|
42
|
138.2 |
59 |
168.8
|
76
|
78.8 |
26 |
109.4
|
43
|
140.0 |
60 |
170.6
|
77
|
80.6 |
27 |
111.2
|
44
|
141.8 |
61 |
172.4
|
78
|
82.4 |
28 |
113.0
|
45
|
143.6 |
62 |
174.2
|
79
|
84.2 |
29 |
114.8
|
46
|
145.4 |
63 |
176.0
|
80
|
86.0 |
30 |
116.6
|
47
|
147.2 |
64 |
|
|
87.8 |
31 |
118.4
|
48
|
149.0 |
65 |
|
|
|
|